Heraeus Vötsch climate test chamber with humidity, model VC³ 0100, temperature range 0°C to +90°CHeraeus Vötsch
Vötsch Klimaprüfschrank
Heraeus Vötsch climate test chamber with humidity, model VC³ 0100, temperature range 0°C to +90°C
Heraeus Vötsch
Vötsch Klimaprüfschrank
Állapot
Használt
Helyszín
Borken 

Alapadatok
- Gépmegnevezés:
- Heraeus Vötsch climate test chamber with humidity, model VC³ 0100, temperature range 0°C to +90°C
- Gyártó:
- Heraeus Vötsch
- Modell:
- Vötsch Klimaprüfschrank
- Állapot:
- használt
Ár és helyszín
- Helyszín:
- Einsteinstraße 8a, 46325 Borken, Deutschland

Hívás
Ajánlat részletei
- Hirdetés azonosító:
- A222-70352
- Referencia szám:
- 24236
- Frissítés:
- utoljára ekkor: 15.10.2026
Leírás
Vötsch
Type: VC³ 0100
Vötsch Climate Test Chamber, Air-Cooled
Test chamber dimensions: Height 950 mm x Width 1100 mm x Depth 950 mm
Device dimensions: Height 2000 mm x Width 1300 mm x Depth 1916 mm
Test chamber volume: 990 liters
Temperature tests:
Minimum temperature -0°C
Maximum temperature +90°C
Temperature change rate (cooling): 0.2 K/min
Temperature change rate (heating): 0.5 K/min
Csdpfx Aoziypujmnjhd
Temperature deviation (over time): ± 0.1 to ± 0.5 K
Temperature homogeneity (spatial): ± 0.5 to ± 1.0 K
Thermal compensation at +20 °C: 350 W
Climate tests:
Minimum temperature +10°C
Maximum temperature +90°C
Dew point temperature range: +4°C to +89.5°C
Humidity range: 10 to 98% RH
Humidity deviation (over time): ± 1 to ± 3% RH
Temperature deviation (over time): ± 0.1 to ± 0.3 K
Temperature homogeneity (spatial): ± 0.5 to ± 1.0 K
Voltage: 1/N/PE AC 230V ±10% 50Hz
Rated power: 2.3 kW
Rated current: 10 A
Refrigerant: R-404A
Weight: approx. 1400 kg
For your safety as a buyer, please note the following information:
The following steps are performed on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If necessary, refill with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (See image)
(Changes and errors in the technical data are subject to change!)
We will be happy to answer any further questions you may have by telephone.
A hirdetés automatikusan lett lefordítva. Fordítási hibák előfordulhatnak.
Type: VC³ 0100
Vötsch Climate Test Chamber, Air-Cooled
Test chamber dimensions: Height 950 mm x Width 1100 mm x Depth 950 mm
Device dimensions: Height 2000 mm x Width 1300 mm x Depth 1916 mm
Test chamber volume: 990 liters
Temperature tests:
Minimum temperature -0°C
Maximum temperature +90°C
Temperature change rate (cooling): 0.2 K/min
Temperature change rate (heating): 0.5 K/min
Csdpfx Aoziypujmnjhd
Temperature deviation (over time): ± 0.1 to ± 0.5 K
Temperature homogeneity (spatial): ± 0.5 to ± 1.0 K
Thermal compensation at +20 °C: 350 W
Climate tests:
Minimum temperature +10°C
Maximum temperature +90°C
Dew point temperature range: +4°C to +89.5°C
Humidity range: 10 to 98% RH
Humidity deviation (over time): ± 1 to ± 3% RH
Temperature deviation (over time): ± 0.1 to ± 0.3 K
Temperature homogeneity (spatial): ± 0.5 to ± 1.0 K
Voltage: 1/N/PE AC 230V ±10% 50Hz
Rated power: 2.3 kW
Rated current: 10 A
Refrigerant: R-404A
Weight: approx. 1400 kg
For your safety as a buyer, please note the following information:
The following steps are performed on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If necessary, refill with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (See image)
(Changes and errors in the technical data are subject to change!)
We will be happy to answer any further questions you may have by telephone.